- BSATET - BetaStar Advanced for Tetracyclines, Safety Data Sheet [English]
The BetaStar Advanced for Beta-lactams kit contains:
- 25 test strips for detecting tetracyclines stored in tube with a desiccant in the lid
- 25 disposable 400 μL poly-pipettes
- Raptor Integrated Analysis System (Neogen item number: 9680)
- Package of 50 Raptor cartridges for test strips (Neogen item number: 9681)
- Dymo Label Writer 450 Printer (Neogen item number: 9687)
- Dymo replacement paper (Neogen item number: 9688)
- Tetracycline Positive Control (Oxytetracycline at 300 ± 30 ppb) (Neogen item number: TET010)
ppb |
Oxytetracycline |
Chlortetracycline |
Tetracycline |
0 |
0% |
0% |
0% |
50 |
0% |
0% |
0% |
100 |
0% |
0% |
0% |
150 |
40% |
0% |
17% |
200 |
100% |
13% |
93% |
250 |
100% |
87% |
100% |
300 |
100 |
100% |
100% |
Tolerance/safe level (ppb) 1 |
300 |
300 |
300 |
Calculated 90 – 95% 2 |
189.6 |
254.3 |
244.8 |
- 1 The tolerance level for each of the tetracycline antibiotics has been set by the FDA as the sum of all tetracyclines